Which is nearly 4 times and 2 ½ times respectively higher than HP required in mechanical aeration system.
We are sure that this is due to the Closer Distance (about 220mm) placement of the membrane is adopted in Western Countries. This is the exact site - experience report of Ashley Water Treatment Plant, in Delaware country, OHIO. (*)
M/s. Schumacher Catalogue show closer distance of membranes. Kindly refer Enclosure.
We have noticed that one of the suppliers in India offers Disc Diffusers at the distance of 1125 mm and 975 mm distance which is certainly is not adopted in western countries.
Due to unsatisfactory performance of M/S. Metro Dye Chem. - their own private CETP plant at Vatva, GIDC due to diffused aeration system, for their new plant at Umraya, near Baroda, where the supplier had ordered for ADDITIONAL 4 Nos. of 25HP Slow Speed Floating Type Surface Aerators of our ENVIRON make, and are Additionally installed in the aeration tank having already Diffused Aeration System. Thezerox copy of the photograph of the same is enclosed. - Enclosure.
So there are so many examples showing the failures of this system in India, because of the WRONG installations (larger distance between diffuser) of the system. In the beginning of the plant upto eight to nine months, it may work, but once the settlement of solids at bottom starts, due to development of Septic conditions, the system failure starts.
CASE STUDY : CETP, VATVA GIDC (AHMEDABAD)
In CETP, VATVA GIDC (AHMEDABAD) where Rs. 30 crore have been spent, the Diffused Aeration System is used and failed.
On going through the Data's of effluent GIDC VATVA-CETP you will notice that even though considering 2 Kg of O2 Oxygen required per Kg of Bod. HP of aerators required will be 1320Hp. While existing blowers - 8 Nos. x (132Kw) 177Hp = 1416Hp are used. Therefore saving in Energy with surface mechanical aeration system is 100HP. Saving = 7% (about) with surface aerators.
Calculations :
Flow = 16000 M3 / day, BOD = 1200 ppm
Kg of BOD / Day = 16000 x 1200 / 1000 = 19200 Kg / day.
Kg of O2 / day = 38000 Kg / Day.
Hp of Aerators required = 38000 / 24 x 1.2 = 1320 Hp
So, even though claimed, there is No Saving In Energy with Diffused Aeration System.
Now, for equalization Tanks: Volume 16580 M3, Blowers = 3Nos. x 160 kw = 480 kw = 645 HP are installed.
Generally for Equalization, the energy required is 20 Watts/M3. So the total Horse Power required for Floating Mixer or Floating Aerators with Draft Tube required would be 16580 M3 x 0.02kw / M3 = 335 kw = 445HP.
So In spite Of Spending More Energy For Diffused Aeration System Compared To Aerators, They Are Facing Trouble Of Heavy Settlement On The Floor Level Of 60m Dia. Rcc Aeration Tank.
So We Do Not See Any Energy Saving In Diffused Aeration System, If Correctly Adopted.
There are so many cases of the failures of systems in India, which we have observed.
So before preferring the Diffused Aeration System to mechanical aerators systems, kindly think of Mixing Criteria requirement in Aeration, which requires close placement (200 to 220 mm.) of the membranes, otherwise there will be lots of Dead Pockets, settlement of the solids and creation of the septic condition would occur at the floor level of the aeration tank, if the distance is kept more than 220 to 250 mm. between two membranes.
This is written, just to share with you our three decades Site experience in the field of Effluent Treatment Plant as an equipment manufacturers.
ALSO THE AIR AT HIGHER TEMPERATURE IS COMING OUT FROM BLOWER WHICH RAISES THE TEMPERATURE OF THE EFFLUENT ABOVE 40o C SO
1. AT HIGHER TEMPERATURE BACTERIA CANNOT SURVIVE AND ALSO,
2. AT HIGHER TEMPERATURE THE SOLUBILITY OF OXYGEN IN WATER IS LESSER. SO YOU MAY DESIRED DISSOLVED OXYGEN. THE CHART OF SOLUBILITY OF OXYGEN IN WATER IS ENCLOSED - Enclosure
Secondly, we cannot avoid to compare from maintenance point of view - the MAINTENANCE of the MECHANICAL AERATION SYSTEM is much EASIER, ECONOMICAL and TIME SAVING compared to DIFFUSED AERATION SYSTEM.
The maintenance of the Mechanical Aeration System can be done on the platform of the Aeration tank (maintenance of the gearbox only) with disturbing the effluent in the aeration tank. While to maintain the Diffused Aeration System, you have to empty and clean the whole aeration tank then and then only you can install and maintain the Diffuseers at the bottom of the Aeration tank. |